YesPermit

Egress window requirements, explained

Under the 2021 International Residential Code, an emergency escape window needs a net clear opening of at least 5.7 square feet, at least 24 inches high and 20 inches wide, with the bottom of the opening no more than 44 inches above the floor. A window below grade needs a well at least 9 square feet, 36 inches wide and deep, with a ladder beyond 44 inches.

Updated

Editorial lead: The YesPermit team

Rather not do this yourself? We prepare your permit file for your address, and revise it until approved.

Get my permit · $499

Key facts

An unfinished basement with insulated walls before drywall

What is an egress window for?

An egress window, which the code calls an emergency escape and rescue opening, is a window or door that someone can climb out of in a fire and that a firefighter can climb into. The International Residential Code (IRC) asks for one in basements, habitable attics and every sleeping room, and, where a basement has bedrooms, in each of those bedrooms. It must open onto a public way, or onto a yard or court at least 36 inches wide that leads to one[1].

Where do you need one?

Under the 2021 IRC[1]:

  • Every sleeping room, wherever it is in the house.
  • Basements and habitable attics: at least one opening, with exceptions for basements used only for mechanical equipment and not over 200 square feet.
  • Existing basements being finished: Section R310.7 requires an escape opening in new sleeping rooms; "other than new sleeping rooms, where existing basements undergo alterations or repairs, an emergency escape and rescue opening is not required."

State codes can ask for more. Monticello, Minnesota, quoting the 2020 Minnesota State Building Code, requires an opening for basements with habitable space and every sleeping room below the fourth story[2]. Castle Pines, Colorado, says all basements and sleeping rooms must have an emergency escape window or exterior door[3]. Under those rules a basement family room alone triggers the window.

The size rules

Item2021 IRC rule
Net clear openingAt least 5.7 sq ft (5 sq ft for a grade-floor opening)
Clear heightAt least 24 inches
Clear widthAt least 20 inches
SillBottom of the clear opening at most 44 inches above the floor
OperationFrom inside, without keys, tools or special knowledge

IRC Sections R310.1.1 and R310.2.1 to R310.2.3[1].

"Net clear" means the opening you get by operating the window normally[1]: not the rough opening, not the frame, not the glass. A double-hung window opens only half its height, a slider half its width; a casement opens almost all of it.

Why 20 by 24 inches is not enough

The two minimums multiplied give 480 square inches, or 3.3 square feet: far from 5.7. Monticello's handout says it plainly ("Using both minimum figures will not obtain the required 5.7 square feet") and publishes the pairs that work[2]:

Clear width (in)2022242628303234.2
Minimum clear height (in)4137.334.231.629.327.425.724

To check any window: multiply the clear width by the clear height in inches and divide by 144. A casement with a 24 by 36 inch clear opening gives 864 / 144 = 6.0 square feet.

Window wells

A window whose sill is below the ground outside needs an area well[1]:

  • Size: at least 9 square feet, with a horizontal projection and a width of at least 36 inches, large enough to open the window fully.
  • Ladder or steps when the well is deeper than 44 inches: permanently fixed, not blocked by the open window. Ladders at least 12 inches wide inside, projecting 3 inches from the wall, rungs no more than 18 inches apart; steps at least 12 inches wide with 5 inch treads and 18 inch maximum risers. They may encroach 6 inches into the required well size.
  • Drainage to the foundation drain, unless the soil drains well.
  • Covers and grilles only if they release from inside without a key, a tool or extra force.

Monticello adds a cold-climate note: wells less than 32 inches from the basement floor to their bottom may need extra exterior insulation to protect the footing from frost[2].

Under a deck or porch

An escape window under a deck, porch or cantilever must open fully and leave a path at least 36 inches high and 36 inches wide to the yard (IRC R310.2.4)[1]. Check it before adding a deck over a basement window.

Replacing an existing window

The 2021 IRC lets a replacement window skip the size rules if it is the manufacturer's largest standard size that fits the existing frame or rough opening and keeps the same or a larger opening, outside a change of occupancy (R310.5)[1]. Where an existing basement gains a use that requires an escape opening, an existing operable window may count if it gives at least 4 square feet, 22 inches high and 20 inches wide (R310.7.1)[1].

If you are replacing bedroom windows rather than finishing a basement, how to measure the net clear opening of a casement, a double-hung and a slider, which cities accept the largest window that fits and which, like Broomfield, Colorado, ask for today's full size, and what changes when you widen the opening are in our Window, Door and Egress Opening Permit Handbook (PDF).

A finished basement with carpet, recessed lights, a sitting area and a dining table
A finished basement with carpet, recessed lights, a sitting area and a dining table. Illustrative photo. Photo: smadden, CC BY-SA 2.0

What to put on the plan

Castle Pines asks basement plans to list window sizes and types and to identify the emergency escape windows[3]; Monticello asks for window sizes and locations[2]. For each escape window, write on the plan the model, the net clear width and height, the area, the sill height and the well size: that is what the reviewer and the inspector check.

  • Permit Kit$349
  • Kit + Review$399
  • All-in$499

Your permit file, prepared for your address

We handle the permit. You build your project.

  • Your city's rule, for your addressThe code section, its link and the date we checked it.
  • Site plan and dimensioned drawingsDistances to your property lines, ready for the application.
  • The form, where to file it, and the published feePlus the documents list and an HOA request template.
  • Reviewed, then revised until approvedWith All-in, after every comment from the city, for up to 6 months.
Approved or your money backFull refund if the city refuses your permit for a written requirement we should have caught. Read the conditions

Common questions

What size does an egress window have to be?

Under the 2021 IRC, a net clear opening of at least 5.7 square feet, at least 24 inches high and at least 20 inches wide; a grade-floor opening may be 5 square feet. The dimensions are those you get by opening the window normally, not the frame or glass size.

Is 20 by 24 inches enough for an egress window?

No. Monticello, Minnesota, points out that using both minimums does not give 5.7 square feet; 20 by 24 inches is only 3.3 square feet. A 20 inch wide opening needs about 41 inches of clear height, a 24 inch wide one about 34.2 inches.

How high can an egress window sill be?

The bottom of the clear opening may be at most 44 inches above the floor under IRC Section R310.2.3.

When does a window well need a ladder?

When it is more than 44 inches deep. The ladder is permanently fixed, at least 12 inches wide inside, projects at least 3 inches from the wall and has rungs no more than 18 inches apart for the full height of the well.

Does every finished basement need an egress window?

Under the 2021 IRC, a new bedroom in an existing basement does, while other alterations of an existing basement do not. Some state codes ask for more: Monticello, Minnesota, and Castle Pines, Colorado, require one for basements with habitable space or for all basements. Ask your building department which rule it enforces.

  • Permit Kit$349
  • Kit + Review$399
  • All-in$499

Your permit file, prepared for your address

We handle the permit. You build your project.

  • Your city's rule, for your addressThe code section, its link and the date we checked it.
  • Site plan and dimensioned drawingsDistances to your property lines, ready for the application.
  • The form, where to file it, and the published feePlus the documents list and an HOA request template.
  • Reviewed, then revised until approvedWith All-in, after every comment from the city, for up to 6 months.
Approved or your money backFull refund if the city refuses your permit for a written requirement we should have caught. Read the conditions
Rather hire a contractor to build it?Tell us about the job: we pass your request to partner contractors in your area. No cost to ask, no obligation to hire.
What do you need?
When would you like the work done?

Sources

  1. International Code Council, 2021 International Residential Code, Chapter 3 Building Planning (Section R310 Emergency Escape and Rescue Openings). Checked October 31, 2026.
  2. City of Monticello, Minnesota, Building Safety Department, Basement Finishing Guide (2020 Minnesota State Building Code). Checked October 31, 2026.
  3. City of Castle Pines, Colorado, Residential Basement Finish, Building Guide for Homeowners. Checked October 31, 2026.
$499Approved or refunded
Get my permit · $499